Products

Featured products

Customized Lanen Equipment Shelter Container

  • Customized Lanen Equipment Shelter Container
  • Customized Lanen Equipment Shelter Container
  • Customized Lanen Equipment Shelter Container
  • video
  • Lanen
  • Foshan
  • 10 days
  • 1000sets/month
Lanen's Equipment Shelter Container is a customized, manufacturer-built energy solution on a Modified Shipping Container. It integrates batteries, BMS, PCS/EMS, HVAC and HFC-227ea fire, delivering 1MW/1MWh (40-ft), -40 to 70 C, 50 mm A-class insulation, >=110 um coatings; beyond a shipping container house.

Lanen’s Equipment Shelter Container is a containerized energy storage solution built on a Modified Shipping Container platform and engineered for harsh, real‑world deployment. It integrates battery racks, high‑accuracy BMS, PCS, EMS, dedicated HVAC, fire suppression, and environment monitoring into a single, factory‑tested unit. This is not a generic shipping container house; it is an industrial‑grade, customized system designed by a manufacturer that understands power, safety, and uptime.

What sets this product apart is the level of requirement we design to—and consistently meet. The shell uses high‑weathering steel with a dual‑skin construction and A‑class fire‑rated rock wool insulation at 50 mm. The thermal design targets a 55 C indoor‑outdoor delta with a heat transfer coefficient ≤1.5 W/(m2·K), supporting ambient conditions from -40 C to 70 C. Structural design meets a static load ≥36 t, and the three‑layer anti‑corrosion coating totals ≥110 μm (zinc‑rich primer 30 μm + epoxy 40 μm + acrylic topcoat 40 μm). Paired with routine maintenance, the Equipment Shelter Container is built to resist corrosion, UV, dust/sand, water ingress, shock, theft, and high winds over a 25‑year horizon.

As a customized manufacturer, Lanen delivers the Equipment Shelter Container in 20‑ft or 40‑ft formats. A typical 40‑ft build integrates a 1 MW/1 MWh system in one enclosure; for longer durations, we support PCS‑to‑battery ratios such as 250 kW:1 MWh (1:4). For 1 MW containerized converters, we adopt a front‑in, rear‑out airflow design to optimize ducting, cable routing, and maintenance aisles while keeping transport and O&M costs low.

Equipment Shelter Container

System Architecture

  • Battery Room: LFP, other lithium chemistries, or lead‑carbon/lead‑acid options; front‑service battery racks (each cabinet ≥1 t load), high‑precision BMS with cell‑level voltage/current measurement and active balancing; smoke detection, lighting, cameras, and heptafluoropropane (HFC‑227ea) fire suppression.

  • Equipment Room: PCS for bidirectional AC/DC conversion (grid‑tied and islanded), EMS for real‑time power monitoring via smart‑meter interfaces; supports black‑start and power/voltage/frequency support to site loads.

  • Thermal & Airflow: Dedicated HVAC with replaceable intake filters; container insulation uses double steel skins with 50 mm A‑class rock wool to meet U ≤1.5 W/(m2·K) at 55 C delta; layout eliminates hot/cold stratification and improves floor‑level temperatures.

  • Safety & Access: Fire partition between rooms; outward push‑latch escape door; mechanical interlocks; four external, symmetric grounding points; independent subsystems for power, temperature control, insulation, flame retardancy, fire alarm, egress, and emergency response.

  • Monitoring: Data acquisition and control for voltage/current, synchronized telemetry, remote commands; optional remote client/app for equipment status and battery health.

Why Lanen

  • Built for extremes: -40 C to 70 C, UV, dust/sand, water, shock, high winds, and theft resistance.

  • Industrial shell: Corten‑grade steel or equivalent, double‑skin with 50 mm A‑class rock wool, 25‑year anti‑corrosion design, ≥110 μm coatings, four‑corner grounding.

  • Power‑ready: 1 MW/1 MWh in one 40‑ft Equipment Shelter Container; flexible ratios (e.g., PCS 250 kW with 1 MWh battery) for long‑duration storage.

  • Safety‑first: HFC‑227ea fire system, smoke/temperature/humidity sensing, sealed doors with 18 mm gasket allowance for tight closure, segregated rooms, escape door, and mechanical interlocks.

  • Manufacturer advantage: Lanen is a customized manufacturer, not a reseller. We tailor Modified Shipping Container builds to your power profile, thermal envelope, logistics, and codes.

Key Specifications at a Glance

  • Enclosure: Modified Shipping Container, double steel skins, 50 mm A‑class rock wool; U ≤1.5 W/(m2·K) at 55 C delta; ambient -40 C to 70 C.

  • Structure: Static load ≥36 t; anti‑corrosion coating total ≥110 μm; external four‑point grounding with marked lugs.

  • Layout: Battery Room + Equipment Room with fire barrier; outward escape door; maintenance aisle; front‑in / rear‑out thermal path for high‑power PCS arrays.

  • 40‑ft Example: 1 MW/1 MWh integrated; PCS:Battery configurable at 1:1 or 1:4 (e.g., PCS 250 kW, battery 1 MWh).

  • Fire & HVAC: HFC‑227ea fire suppression; smoke/temperature/humidity sensors; dedicated HVAC with replaceable filters; thermal management to extend battery life.

  • Racks & Floor: Front‑service racks, each cabinet ≥1 t; typical floor panels 28 mm thickness for rugged service.

Equipment Shelter shipping Container

Buyer and Producer Questions Answered

  • Can it survive outdoors for decades?
    With periodic maintenance, the shell is engineered for 25 years without failure from corrosion, fire, water, dust, or UV. Coatings total ≥110 μm (30 μm zinc‑rich + 40 μm epoxy + 40 μm acrylic), and the structure uses high‑weathering steel.

  • How does it stay safe?
    Rooms are fire‑segregated; the Battery Room has HFC‑227ea (heptafluoropropane) suppression, smoke/temperature/humidity sensors, and an outward push‑latch escape door. The BMS offers high‑accuracy cell voltage/current measurement and balancing to reduce circulating currents and improve system efficiency.

  • What power/time configurations are supported?
    A standard 40‑ft Equipment Shelter Container integrates 1 MW/1 MWh. For long‑duration use, a 1:4 ratio is common (PCS 250 kW with 1 MWh battery). PCS supports grid‑tied energy exchange and off‑grid operation with voltage/frequency support and black start.

  • How is thermal performance guaranteed?
    Double steel skins with 50 mm A‑class rock wool achieve U ≤1.5 W/(m2·K) at a 55 C internal‑external differential. Operating range is -40 C to 70 C. For 1 MW converter bays we use a front‑in, rear‑out airflow to stabilize temperatures and prevent hot spots.

  • What about dust and sand?
    All intakes use replaceable filter media; doors are sealed with an 18 mm allocation for gaskets to maintain tight closure and low leakage, limiting ingress during sandstorms.

  • Is it robust enough for transport and installation?
    Yes. The enclosure targets a static load ≥36 t, includes four symmetrical grounding points, and the interior layout provides cable routes and a maintenance aisle. The Modified Shipping Container format simplifies lifting, trucking, and siting.

  • What’s inside the Battery Room?
    Front‑service racks (each cabinet ≥1 t), BMS control cabinet, HFC‑227ea cabinet, HVAC, lighting, smoke detection, cameras, and optional remote client/app monitoring.

  • What’s inside the Equipment Room?
    PCS cabinets and EMS. EMS reads real‑time grid power via smart meters, monitors load variations, and automates dispatch; PCS controls charge/discharge and AC/DC conversion for both grid‑tied and islanded modes.

  • Is it a shipping container house product?
    Externally it resembles a shipping container house, but functionally it is a high‑demand Equipment Shelter Container for energy storage. We build on a Modified Shipping Container foundation with industrial insulation, fire systems, and electrical gear.

  • Can Lanen customize the build?
    Yes. As a customized manufacturer we tailor battery chemistry (lithium iron phosphate and others), PCS sizing, HVAC, fire systems, monitoring, and enclosure details (20‑ft or 40‑ft; door, filter, and rack layouts) to your site, codes, and logistics. Optional features can include different material grades and finish systems for high‑salt or desert regions.

Use Cases

  • Renewable plants (solar, wind) for peak‑shaving and firming

  • Thermal plants for frequency and reserve support

  • Islands, campuses, schools, labs, factories, and large load centers needing resilient power

  • Sites needing fast deployment, minimal civil works, and a compact Modified Shipping Container footprint

shipping Container

Conclusion

Lanen’s Equipment Shelter Container brings utility‑grade storage to a compact, transportable enclosure. By combining a Modified Shipping Container shell, 50 mm A‑class insulation, ≥110 μm corrosion protection, 25‑year outdoor design, HFC‑227ea safety systems, and flexible PCS:Battery ratios up to 1 MW/1 MWh per 40‑ft unit, we deliver a rugged, customized solution from a manufacturer focused on reliability and speed of deployment. If you are exploring a containerized, customized shipping container house–style enclosure for energy storage, talk to Lanen—we will configure the right Equipment Shelter Container for your site and grid.


Get the latest price? We will reply as soon as possible (within 12 hours)